MOTOR
GEARBOX ASSY
TOP CAM
LOWER CAM
MICROSWITCH
INSTALLATION OF ELECTRONIC CONTROL BOX
MOUNTING CONTROL BOX
STEP 4
The Control Box is to be mounted nearby the Drive Unit
using (4) 6mm screws. The mounting coordinates is 55mm x
275mm. When locating the Control Box allow ample space
around the unit for easy access and wiring connections.
Remove cover from control box.
Determine which leaf you would like to open first and close
last. This gate leaf must be connected to Motor 1 (M1) termi-
nals on the control board. Connect the Control Board with
Drive Unit(s) using 5 core cable. For detail of electrical in-
stallation see pages 10 & 11.
Note: The installation hand is determined from inside the gate
looking out to the street.
CAUTION: DO NOT USE ANY CABLE WHICH
CARRIES GREEN/YELLOW WIRES AS THIS SIGN-
IFIES EARTH, AND DOES NOT COMPLY WITH
ELECTRICAL AUTHORITY REGULATIONS.
LIMITS AND CAMS SET-UP
STEP 5
Setting of limits for open and closed position is performed
with opener in manual position (Fig 3 & 4).
DO NOT SWITCH ON POWER OR ENGAGE
MOTOR DRIVE YET.
For Right Hand Side installation:
When gate is closed turn lower cam in a clockwise direction
(Fig 10) until an audible click can be heard from the lower
micro-switch. Open the gate to the required opening position
and turn top cam in an anticlockwise direction until a click
can be heard from top micro switch.
For Left Hand Side installation:
When gate is closed turn top cam in a clockwise direction
(Fig 10) until an audible click can be heard from the top
microswitch. Open the gate to the required opening position
and turn lower cam in an anticlockwise direction until a click
can be heard from lower microswitch.
Page 8
ANTENNA
Mount the antenna at or above the height of the gate
or fence for optimal reception, which ever is higher.
(Fig 9). Do not cut antenna or coaxial cable.
FIG. 10
FIG. 9